27 Fire Delay (Latch)
This output is activated whenever a Fire zone is activated. Activation is delayed subject to
the 03=Abort Time parameter. The Fire Delay output is not subject to the Re-arm
parameter. It latches on and remains active until a valid code (type 2 or above) is entered.
28 No Re-Arm (Latch)
This output is activated on a full alarm event during the set state, and is subject to the Bell
Delay parameter. The No Re-arm output is similar to the strobe output, but it stays on at the
end of the bell time, until unset.
29 Timer A (Reflex)
This output is controlled by the Timer-A option (refer to Timers [65]) and activates in
accordance with the programmed on and off times assigned to the function.
30 Timer B (Reflex)
This output is controlled by the Timer-B option (refer to Timers [65]) and activates in
accordance with the programmed on and off times assigned to the function.
Note: If the Timer A or B outputs are programmed as Latch mode, then they can only be
reset by a user code with access to all of the groups assigned to the relevant timer.
32 Zone Omit
This output is activated by 11=OMIT ZONES or by 54=LINKS, as soon as a zone is
omitted from the system. If the Output Mode attribute is assigned as:
Reflex (default), the output remains active until the zone is reinstated.
Latch, the output is reset on entry of a valid code.
34 Custom A (Latch)
This output is activated whenever a Custom-A zone is activated.
35 Custom B (Latch)
This output is activated whenever a Custom-B zone is activated.
37 Reset RQD (Latch)
This output is activated when a system, tamper or PA alarm occurs that needs to be reset.
Refer to Parameters [51] for details modifying the code levels assigned to the 06=System
Reset, 07=Tamper Reset and 22=PA Reset parameters.
40 Fail Set (Latch)
Fail Set is activated if the system (or assigned groups) fails to set within the time assigned in
35=Fail to Set (refer to Parameters [51]).