Galaxy Flex Installer Manual Override faults and tampers
35
determined on site. The cause code values should be determined in conjunction with the
Alarm Receiving Centre (ARC).
Override faults and tampers
Whenever a user logs in, the display shows any unrestored faults and tampers. If the
condition cannot be cleared and restored, the user may be able to override the condition.
When a user tries to set the system, any conditions that are present are displayed. The user
can scroll through multiple conditions. If the user has the authority to override the condition,
the following display accompanies the condition:
If the user cannot override the condition, ENT to Continue will not be displayed.
The user can override each authorized condition by pressing ent while the condition is
displayed on the keypad. Each condition is individually displayed and overridden.
Pressing ent omits the condition for one set period only.
Pressing esc returns to the previous banner.
When setting the system with an overridden fault or tamper condition, the display indicates
the overridden function in place of the set mode by showing the omit message as detailed in
the omit menu function. The Override condition is logged, and will last for one set period
only. When all the groups that are affected by the override condition become unset, the
override status is cleared. An override restore is logged at unset.
If, during a setting attempt, there are conditions that haven’t restored and cannot be
overridden, then the system will not set. The display shows the CALL MANAGER
RESET REQUIRED banner with a short beep every 30 seconds.
Setting features
The control panel provides a range of features to help the user to set and unset the system.
Show set status
Ensure that Show Status is enabled (refer to Show Status [58.6]). Press
and #
simultaneously to show the group set status.
= Fault
R = Ready
S = Set
P = Part Set
L = Locked Out
– = Group not assigned to keypad
Note: The Show Status indicates the set conditions of groups when the system is set
(keypad blank) or unset (normal banner). Show Status does not operate while
engineer mode is accessed.
STATUS 12345678
Groups RRSRLPFP
ALERT-BATT LOW
ent=CONTINUE SET
group block