Communications [56] Galaxy Flex Installer Manual
132
3=Call Back Up to five telephone numbers can be programmed, with which
Remote Servicing can instruct the panel to call back.
Notes:
1. If Manager Authorize is selected as the Remote Access Mode, the telecoms module
can only make outgoing calls. This allows another telephone, fax or answering machine
to be connected to the line without interference from the telecom module when calling
into the premises.
2. If Call Back is selected, access to the panel is denied unless the call back option in
Remote Servicing is used to initiate the connection.
Call Home [56.1.13] Not used
Alarm Monitoring [56.1.14]
Use this option to allow events to be dialled to a computer with Alarm Monitoring software.
Alarm events information is only transmitted when all of the alarms have been sent to the
ARC (or all communication attempts have been unsuccessfully made). If a new alarm event
occurs while the system is transmitting in the Alarm Monitoring mode, the transmission is
terminated and the alarms are sent to the ARC using the primary format selected.
The menu structure and programming of the Alarm Monitoring options are identical to the
SIA format. Refer to SIA [56.1.01.2].
SMS [56.1.17]
Use this option to generate and transmit SMS text messages in response to events that occur.
1=Mobile No.(s) Press ent to access and enter up to three mobile numbers (22 digits
max.) of message recipients.
2=Centre No. The phone number (22 digits max.) of the SMS centre. Each operator
has a different number.
3=Format The options are:
1=TAP For mobile phones (UK)
2=UCP (SMS) For mobile phones (outside UK)
3=UCP (Minicall) For alpha pagers
4=UCP (Numeric) For numeric pagers
4=Site ID A 16 character alphanumeric string used to identify the panel/site
sending the message. If the format is UCP (Numeric), then the site ID is
numeric only, and only the first four characters are sent out.
5=Password A 16 character string that is an optional field required by some paging
centres.