Loading...
Galaxy Flex Installer Manual Access Control [69]
179
69 = Access Control (continued)
 3 = DCM
 1 = DCM Parameters MAX DCM (select)
 1 = Descriptor ABCDE_ (9 characters)
 3 = System Group
 5 = Reader (01 or 02)
 01 = Descriptor (ABCDE_ 9 characters)
 02 = Relay Duration - 0-60 seconds (default = 05)
 03 = Open Timeout - 1-60 seconds (default = 10)
 04 = Group Config
 1 = Alarm Group
 2 = Group Restrict
 3 = Exit Group
 05 = Emergencies 0 = Disabled, 1 = Enabled
 06 = Security
 1 = Nightlock 0-4 weekly schedules
 2 = Unlock Time 0-4 weekly schedules
 3 = Dual Mode
 1 = Disabled
 2 = Card and Card
 3 = Card and Pin
 4 = Dual Time - Option not available
 07 = Menu Recall
 1 = Menu Function 11-72 (** = not used)
 2 = Menu Mode
 1 = Triple Repeat
 2 = Recall Button
 3 = Keypad ** - Keypad
# = Enable
 2 = Card Format
 0 = 26bit
 1 = Crp 1K 35bit
 2 = 37bit no FC
 3 = Northern 34
 4 = Custom
 1 = Format Name
 2 = Card Length
1 = 26 Bit, 2 = 27 Bit, 3 = 32 Bit, 4 = 34 Bit
5 = 35 Bit, 6 = 37 Bit,7 = 40 Bit
 3 = Card Number
 1 = Start point
 2 = Field Length