Appendix B: SIA and contact ID event codesGalaxy Flex Installer Manual
198
Ev SIA Event Log Log Event Ev Type Trigger Contact
Description Event Description ID Event
CL Closing Report FULL SET Full set USER 10.SETTING 401
FULL SET Set by keypad EVENT 10.SETTING 401
KSW SET Keyswitch set ZONE 10.SETTING 409
CP Auto. Closing REARM Re-arm after alarm EVENT 10.SETTING 463
CR Recent Close RECEN.SET Previous alarm was within EVENT 2.INTRUDER 459
5 mins of set
CT Late to Open TIMEOUT Entry timeout EVENT 10.SETTING None
D - Access
DD Access Denied Invalid Card MAX tag unknown MOD 17.MAXTAG 421
DF Door Forced MAX ALARM Door contact broken MOD 4.SECURITY 423
17.MAXTAG
DCM EVENT Door contact broken MOD 4.SECURITY 423
DG Access Granted LEGAL CD Legal code entered USER 16.LOG 462
LEGAL CD ATM code entered USER 16.LOG 462
Valid MAX tag accepted USER 17.MAXTAG 422
DK Access Lockout ILL-CODE Illegal code entry USER 16.LOG 421
REJECT CARD Illegal MAX tag USER 17.MAXTAG 421
FOB REJECT Illegal Fob ZONE 10.SETTING 421
DK Access Lockout DCM EVENT Invalid Card Reader Lockout USER 16.LOG 421
10.SETTING
17.MAXTAG
DT Door propped DOOR PROP MAX - Door left open MOD 4.SECURITY 426
E - System Trouble
ER Mod Removed REMOVED Module Removed MOD TAMPER 532
ET RF NVM Fail RF MEM! RF NVM RAM Fail MOD TAMPER 333
F - Fire
FA Fire Alarm FIRE+ Fire zone alarm ZONE 6.FIRE 110
FB Fire Bypass OMITTED Fire zone omitted ZONE 8.OMIT 573
FORCEOMT+ Force omit after rearm ZONE 8.OMIT 573
FJ Fire Troub rest LOW RES- Restor zone resistance ZONE 15.TROUBL 380
HIGH RES- Restor zone resistance ZONE 15.TROUBL 380
FR Fire Restoral FIRE- Fire zone restored ZONE 6.FIRE 110
18.ZN RESTO
FT Fire Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL 380
HIGH RES+ High resistance on zone ZONE 15.TROUBL 380
FU Fire Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT 573
FX Fire Test FIRE Fire zone tested ZONE NOT SENT None
SOAK TEST Soak test fire zone act ZONE NOT SENT None
G - Gas (Custom SIA - See Note 2)
GA Alarm Note 1 zone in alarm ZONE 5.CUS ZON Note 1
GB Bypass OMITTED zone omitted ZONE 8.OMIT Note 1
FORCEOMT+ Force omit after rearm ZONE 8.OMIT Note 1
GJ Trouble Rest LOW RES- Restor zone resistance ZONE 15.TROUBL Note 1
HIGH RES- Restor zone resistance ZONE 15.TROUBL Note 1
GR Alarm Restore Note 1 zone restored ZONE 5.CUS ZON Note 1
18.ZN RESTO
GT Trouble LOW RES+ Low resistance on zone ZONE 15.TROUBL Note 1
HIGH RES+ High resistance on zone ZONE 15.TROUBL Note 1
GU Unbypass FORCE OMT- Unomitted after rearm ZONE 8.OMIT Note 1