Galaxy Flex Installer Manual Remote Access [47]
67
Conn. Retry Duration [47.4.4.2]
Use this option to set the time the panel tries to make a remote servicing call. The range is 0
to 24 hours. The default setting is 6 hours, and 0 disables the feature.
Conn. Retry Redial Mode Off [47.4.4.3.0]
Use this option to disable the panel from trying to re-establish a connection.
Conn. Retry Redial Mode Retry [47.4.4.3.1]
The panel initiates a remote servicing call to re-establish a connection. The retry is
controlled by option Retry Interval [47.4.4.1] and Retry Duration [47.4.4.2].
Conn. Retry Redial Mode Direct [47.4.4.3.2]
The panel access mode changes to allow direct access for 30 minutes. This mode operates
when Direct Access is selected in the Service [47.1] option.
Control Upload Eng Prog [47.4.5.1]
Initiates a connection when engineer programming has been modified.
Control Upload User Prog [47.4.5.2]
Initiates a connection when user programming has been modified.
Control Upload Either [47.4.5.3]
Initiates a connection when engineer or user programming has been modified.
Remote Maint [47.4.6]
Use this option to control the mode for automatically initiating communications for remote
routine inspection and maintenance. The panel uploads only the most recent information
available from Diagnostics [61]. No other panel programming is uploaded. There are two
sub-options that control this.
Remote Maintenance Schedule [47.4.6.1]
Use this option to control the schedule for the initiation of communication for remote
routine inspection. The schedule can be set from 0 to 365 days. The default is 0 days, which
disables the function.
Remote Maintenance Advice [47.4.6.2]
Use this option to control the communication initiation method. It can be initiated
automatically by the schedule programmed above or manually by user entry of the Service
PIN code, with or without a notification message. There are three options. The default value
for each is disabled.
1=Code Only Entry of a Service PIN code automatically initiates a remote servicing
connection to call back number 1. The Service PIN code can only be
modified by remote users. When the Service PIN code is entered, it
resets any scheduled connection timers.

Table of Contents

Other manuals for Honeywell Galaxy Flex

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex and is the answer not in the manual?

Honeywell Galaxy Flex Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex
CategoryControl Panel
LanguageEnglish

Related product manuals