Parameters [51] Galaxy Flex Installer Manual
74
Note: If the system is programmed to Autoset and the Exit Time is programmed to 000,
the Exit Time is set to 60 seconds for the Autoset. There is no requirement for a
Push-Set zone to be activated.
Setting Multiple Groups
You can assign a different value to each group. If more than one is group is being set, the
longest exit time is adopted for all groups.
Entry Time [51.05]
This parameter determines the entry time allowed to users when unsetting the system.
The default time is 45 seconds and the range is 0 to 300 seconds. Use 000 seconds to set the
Entry Time to infinity.
You can assign a different value to each group.
Note: A
assigned to a Final zone doubles the programmed Entry Time of the group to
which it is allocated.
System Reset [51.06]
Use this option to select the user type that can reset the system following an intruder alarm.
A remote code can also change this option. The default type is 3 and the range is:
3 to 5 for the user.
6 for the manager.
7 for the engineer.
You can assign a different value to each group.
Note: This option is affected by Reduced Resets [51.55.3].
The panel only requests Engineer Level Reset if alarms have been signalled via the
Communication Module and appropriate type reset is set to 7. If no signal is transmitted, the
reset is automatically reduced to type 6. This feature is only active when the DTMF
signalling format is selected.
Note: This option can also be programmed using Reset Levels [51.65].
Tamper Reset [51.07]
Use this option to select the user type that can reset the system following a tamper. A remote
code can also change this option. The default type is 3 and the range is:
3 to 5 for the user.
6 for the manager.
7 for the engineer.
You can assign a different value to each group.
Note: This option is affected by Reduced Resets [51.55.3].

Table of Contents

Other manuals for Honeywell Galaxy Flex

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex and is the answer not in the manual?

Honeywell Galaxy Flex Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex
CategoryControl Panel
LanguageEnglish

Related product manuals