50 Granit XP User Guide
When External or Interface Cable Power is selected, the scanner charges from the
base’s external power supply, if there is one. If there is no external power supply to
the base, the scanner charges from the interface cable.
When External Power Only is selected, the scanner only charges from the base’s
external power supply. If there is no external power supply, the scanner does not
charge.
Note: If you are using a cordless charge base in Presentation Mode, External Power Only
is the only setting available.
Default = External or Interface Cable Power.
Page
Page Mode
By default, the page button on the base or Access Point pages the scanners associ-
ated with that base or Access Point. If you want the page button on your base or
Access Point to be disabled, scan the Page Mode Off barcode, below. When Page
Mode is off, the base or Access Point will no longer page scanners when the button
is pressed. The red LED on the base or blue LED on the Access Point will remain lit
to indicate that page mode is off. (This light will go out when the button is pressed,
then back on when it’s released.) Default = Page Mode On.
Base Charge Off
* External or Interface
Cable Power
External Power Only
* Page Mode On
Page Mode Off