EasyManuals Logo

Honeywell HVC0001 User Manual

Honeywell HVC0001
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
Owner’s Guide 400-305-000-EFS
10
ENGLISH
Press the main button for 3 seconds at any time (or do not press any button for 60 seconds) to save any changes you have
made and exit the setup menu.
Ventilation Mode
Select Units
(US /Metric)
Set Fan Capacity
(CFM or LPS)
ASHRAE 62.2
Pass/Fail
Set Floor Size
(Sq. ft or Sq. M)
Set no. of
Bedrooms
Press simultaneously
In Ventilation Mode, the controller sets the fan On/Off time to meet ASHRAE Standard 62.2 for
ventilation based on total floor space, number of bedrooms and fan capacity. In this mode, the
fan operates on a 60-minute cycle. For example, if the fan is On for 20 minutes, it will be Off for
40 minutes. To set the Ventilation Mode parameters, press the main button for 3 seconds to
display the setup menu and proceed as shown.
400-305-000-B (69-2316EFS-03).book Page 10 Monday, September 28, 2009 11:06 AM

Other manuals for Honeywell HVC0001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell HVC0001 and is the answer not in the manual?

Honeywell HVC0001 Specifications

General IconGeneral
BrandHoneywell
ModelHVC0001
CategoryController
LanguageEnglish

Related product manuals