Installation Instructions MB-Secure 1000/2000/3000/4000/5000/6000  15 
2.6.2  AWUG DS 6700 / DS 6750 (item no. 057864 / 057865) 
 
Automatic transmission device with modem function and connection technology for PSTN (analog telephone 
network) as well as Ethernet connection technology. Can be integrated via the serial interface. 
Up to 100 transmission channels, 40 control inputs for the control panel as well as 100 function groups for 
Contact ID* are available (* = Contact ID in preparation). 
Programming of the DS 6700 / DS 6750 is carried out completely with IQ PanelControl. 
 
Systems designed according to VdS class C have to be operated with an integrated transmission 
device ( via  serial interface). 
 
Operation of a DS 6700 / DS 6750 transmission device in combination with the MB-Secure control 
panel (firmware version V05.xx) firmware version V07 or higher for the transmission device is absolutely 
necessary. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 1 = * Plug for connection cable (I-BUS) 
 2 = * V.24-interface for RFW 
 3 = Reset button 
 4 = Serial S1 (RS-232) for connecting to the serial interface of the MB-Secure computer/connection PCB 
 (Exclusive wired connection: data bus connection) 
 5 = Ethernet connection RJ 45, 10/100 
 6 = USB port, v1.1 
 7 = * Output “signaling” 
 8 = * Positive drive 
 9 = * Output “resuscitation” for RFW
 
Diagram AWUG DS 6700 / DS 6750