Midas
®
Gas Detector
B-5
Gas Name Formula Range
Lower
Alarm
Limit
Default
Alarm 1
Default
Alarm 2
Sensor Part
Number
Maximum
Sensor
Warm-up Time
(minutes)
Sensor
Cartridge
ID
Gas
ID
Flow
Rate
(cc/
min)
Calibration Bump Test
Recommended
Maximum
Sample Line
Length (m)
End of Lne
Filter
Calibration
Gas
Conc
(ppm)
Output
Equiv.
(ppm)
Exp
Time
(sec)
Recommended
Bump Test
Gas
Conc
(ppm)
Max
Time
(sec)
(Note: Due to U.S. Government regulations, this range may be subject to restrictions requiring special licensing for certain countries outside North America. Contact Honeywell Analytics for eligibility information.)
Hydrogen Sulfide H
2
S 0-40 ppm 4.8 ppm 5 ppm 10 ppm MIDAS-S/E-H2S 10 18 1 500 H
2
S 20 20 300 H
2
S 20 180 30
780248,
1991-0147
or
1830-0055
Hydrogen Sulfide
High Level
H
2
S 0-100 ppm 9.5 ppm 10 ppm 20 ppm MIDAS-S/E-HSH 10 27 1 500 H
2
S 50 50 300 H
2
S 50 180 30
780248,
1991-0147
or
1830-0055
Methane (%LEL)
7
CH
4
0-100%
LEL
1
4.5%LEL 10% LEL 20% LEL MIDAS-S/E-LEL
8
30 25 2 500
H
2
2 vol% 57% LEL 300 H
2
2 vol% 180 30
780248,
1991-0147
or
1830-0055
CH
4
2.5
vol%
50% LEL 300 CH
4
2.5
vol%
180 30
780248,
1991-0147
or
1830-0055
Methyl Fluoride CH
3
F 0-120 ppm 10 ppm 15 ppm 30 ppm MIDAS-S/E-XHF 20
3
34 2 500 HF 5 52.50 300 Cl
2
5 180 30
780248
2
,
1991-0147
or
1830-0055
Nitrogen Dioxide NO
2
0-12 ppm 1.45 ppm 1.5 ppm 3 ppm MIDAS-S/E-NO2 10 20 1 500 NO
2
6 6 300 NO
2
50 180 30
1991-0147
or
1830-0055
Nitric Oxide NO 0-100 ppm 12 ppm 12.5 ppm 25 ppm MIDAS-S/E-NOX 10 19 1 500 NO 50 50 300 NO 50 180 30
780248,
1991-0147
or
1830-0055
Nitrogen Trifluoride NF
3
0-40 ppm 4.0 ppm 5 ppm 10 ppm MIDAS-S/E-XHF 20
3
34 1 500 HF
2
5 23 300 Cl
2
2
5 180 30
780248
2
,
1991-0147
or
1830-0055
1830-
0027
6
Nitrous Oxide N
2
O 0-1000 ppm 125 ppm 250 ppm 500 ppm MIDAS-I-N2O 10 92 1 500 N
2
O 500 500 300 N
2
O 500 180 30
780248,
1991-0147
or
1830-0055

Table of Contents

Other manuals for Honeywell Midas

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Midas and is the answer not in the manual?

Honeywell Midas Specifications

General IconGeneral
Power Supply24 VDC
Detection TechnologyElectrochemical, Infrared
Sampling MethodDiffusion
DisplayLCD
CommunicationModbus RTU, 4-20mA
Operating Temperature-20°C to +50°C
Humidity Range0% to 95% RH (non-condensing)
Target GasMultiple gases
Response Time< 30 seconds
Operating Humidity0% to 95% RH (non-condensing)
Outputs4-20mA
Protection RatingIP66
CertificationsATEX, UL, CSA
Detection GasesOxygen (O2), Carbon Monoxide (CO), Hydrogen Sulfide (H2S), Methane (CH4), and others