EasyManuals Logo

Honeywell Midas User Manual

Honeywell Midas
160 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #160 background imageLoading...
Page #160 background image
Midas
®
Gas Detector
C-3
Sensor Cartridge Warranty
Midas
®
sensor cartridges with part numbers beginning
in MIDAS-S carry a 12 month (1 year) warranty from
switch-on/installation or up to 18 months from the date
of shipment from Honeywell Analytics, whichever is less,
provided this takes place before the “Activate Before”
date on the cartridge. Pro-rata after “Activate Before”/
install by date.
Midas
®
sensor cartridges with part numbers beginning
in MIDAS-E carry a 24 month (2 year) warranty from
switch-on/installation or up to 30 months from the date
of shipment from Honeywell Analytics, whichever is less,
provided this takes place before the “Activate Before”
date on the cartridge. Pro-rata after “Activate Before”/
install by date.
1. The oxygen sensor cartridge is guaranteed to
operate satisfactorily for the period described
above and will be replaced at no charge within
that period only if it will not provide a correct
reading after calibration by Authorized Service
personnel. Physical or chemical damage, resulting
from exposure to improper elements, is not
covered.
2. The combustible (LEL) sensor cartridge is
guaranteed to operate satisfactorily for the period
described above. If it will not provide a correct
reading after calibration by Authorized Service
personnel, it will be replaced at no charge within
that period. This guarantee is void if it has been
contaminated by some unusual substance,
including but not limited to, water and/or other
liquids, oily compounds, corrosives, silicones,
lead vapors, extremely high concentrations of
combustible gases, and various particulates
which may inhibit gas flow to the sensor cartridge
element.
3. The toxic sensor cartridges are guaranteed to
operate satisfactorily for the period described
above. They will be replaced at no charge within
that period only if they will not provide a correct
reading after calibration by Authorized Service
personnel, and only if the sensor cartridge
membranes exhibit no physical or chemical
damage resulting from exposure to improper
substances.
Note that the Midas
®
sensor cartridge stores an
electronic history of each individual sensor cartridge’s
manufacture, warranty and calibration activity that is
accessible by Authorized Service personnel.
Pyrolyzer Warranty
Pyrolyzer units, both Standard and High-Temperature,
(MIDAS-T-00P and MIDAS-T-HTP, respectively) are
warranted for a period of 12 months from initial turn-on
or 18 months from delivery from Honeywell Analytics;
whichever is less and are subject to the same terms
and conditions outlined above. Model MIDAS-T-0P3
is warranted for 24 months from intitial turn-on or 30
months from the date of delivery.

Table of Contents

Other manuals for Honeywell Midas

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Midas and is the answer not in the manual?

Honeywell Midas Specifications

General IconGeneral
Power Supply24 VDC
Detection TechnologyElectrochemical, Infrared
Sampling MethodDiffusion
DisplayLCD
CommunicationModbus RTU, 4-20mA
Operating Temperature-20°C to +50°C
Humidity Range0% to 95% RH (non-condensing)
Target GasMultiple gases
Response Time< 30 seconds
Operating Humidity0% to 95% RH (non-condensing)
Outputs4-20mA
Protection RatingIP66
CertificationsATEX, UL, CSA
Detection GasesOxygen (O2), Carbon Monoxide (CO), Hydrogen Sulfide (H2S), Methane (CH4), and others

Related product manuals