13 As Shipped Configuration Reload Procedure
User can reset the configured values in the device to 'As shipped configuration' by considering the
following procedure:
Note: This As Shipped configuration reload procedure can be done ONLY on IrDA communication.
1. Establish an IrDA communication between 350S and MasterLink software application.
2. After a successful connection to the device, in the MasterLink software application window Click
View/Edit on the Menu bar.
In the View/Edit page, read the item 1613 from Raw Item Access.
If the value is 2121488 then, there is a backup available and the user can proceed with the As
Shipped configuration with the available back up.
But, if the value is not equal to 2121488 then, the device will give an unknown error.
User has to then initiate the configuration reload procedure as explained in the next step below.
User should have 'Modify' and 'Change' privileges to perform the As Shipped Configuration
reload procedure. If not, the device will return an 'Access Disabled Error'.
Note: A device under MC seal cannot be restored to As Shipped configuration.
Navigate to 'Configure by Group'. Click on 'Advanced Options' a new pop-up window 'Raw Item Access'
appears.
Write the value “20139380” into item number 264 and wait for one minute. Then, Disconnect the device.
13 As Shipped Configuration Reload Procedure