Section 6. System Programming
6–17
Q 11, L4 Restore Reporting – Enter the digit for the type of Restore reports to be sent. Program the
actual trouble Restore report code in Submode 2, Question 44, Location 4. Program the actual zone
Restore report code in Submode 2, Question 44, Location 2.
L4
Entry
Send AC
Restore
Send Low
Bat. Restore
Send Zone
Restore
Restore
Follows Loop
0
1
✔
2
✔
3
✔ ✔
4
✔
5
✔
✔
6
✔ ✔
7
✔ ✔ ✔
C
✔ ✔
D
✔
✔ ✔
E
✔ ✔ ✔
F
✔ ✔ ✔ ✔
Send Zone Restore & Restore Follows
Loop: Normally, zone restores are sent at
bell cutoff, when the panel is disarmed,
and when the panel is reset. If you select
Restore Follows Loop, zone Restore
reports will be sent as soon as the zone
restores.
QUESTION 12 SYSTEM OPTIONS
L1 L2 L3 L4
This question defines various system-wide options.
Q 12, L1 – Enter the L1 digit for the desired options from the table that follows.
L1
Entry
No Bell
if Dial
Delay
Fast
Zones
5/6
Double-
Balanced
Zones
0
1
✔
2
✔
3
✔ ✔
4
✔
5
✔
✔
6
✔ ✔
7
✔ ✔ ✔
8
9
✔
A
✔
B
✔ ✔
C
✔
D
✔
✔
E
✔ ✔
F
✔ ✔ ✔
No Bell if Dial Delay: If selected, bell sounding will not occur
until the dialer is activated (bell is delayed by the same amount of
time as the dial delay setting). See Question 19, Location 4 for
setting the dial delay (15–255 seconds) and Submode 2, Questions
1–24, Location 4 to enable the dial delay for each zone.
Fast Zones 5/6: Sets zones 5 and 6 to fast response (10mS). If set,
these zones must be wired as NC loops (cannot be double-balanced
zones or part of zone doubling).
Double-Balanced Zones: Select if using double-balanced zones.
This option allows hardwired zones to be wired such that a tamper
will be detected on an open or a shorted loop.