Section 6. System Programming
6–35
For L1 and L3, make selections from the table below (L1 = 1 & 3 keys; L3 = 7 & 9 keys).
Sounder Options Relay Options
L1/L3
Entry
Silent Keypad
Burg.
Bell Temporal
No
Relay
Mom.
Seconds
Mom.
Minutes Toggle
0
✔
✔
1
✔
✔
2
✔
✔
✔
3
✔
✔
4
✔
✔
5
✔
✔
6
✔
✔
✔
7
✔
✔
8
✔
✔
9
✔
✔
A
✔
✔
✔
B
✔
✔
C
✔
✔
D
✔
✔
E
✔
✔
✔
F
✔
✔
Sounder Options:
Selects the sounding
that will occur when
the designated soft
keys are pressed.
Relay Options:
Selects the type of
relay action when the
designated soft keys
are pressed. See
Questions 32–43 to
program relays.
For L2 and L4, make selections from the table below (L2 = 1 & 3 keys; L4 = 7 & 9 keys).
L2/L4
Entry
Arm
Away
Arm
Stay
Pager
Alert/Trouble
0
1
✔
2
✔
3
✔ ✔
4
✔
5
✔ ✔
6
✔ ✔
7
✔ ✔ ✔
Arm Away/Stay: Selects the arming mode that the
designated soft key will activate.
NOTE: If the panel is not ready, the soft key entry will
force-arm the system.
Pager Alert/Trouble: If selected, a message will be
sent to the pager when the designated soft key is
pressed. This can be used to send a “help me” message.
QUESTION 27 SOFT KEY FUNCTIONS FOR
✱ & # N/U N/U
L1 L2 L3 L4
✱ & # Keys