OMNI624 Installation and Setup Guide
6–36
For L1, make selections from the table below.
Sounder Options Relay Options
L1/L3
Entry
Silent Keypad
Burg.
Bell Temporal
No
Relay
Mom.
Seconds
Mom.
Minutes Toggle
0
✔
✔
1
✔
✔
2
✔
✔
✔
3
✔
✔
4
✔
✔
5
✔
✔
6
✔
✔
✔
7
✔
✔
8
✔
✔
9
✔
✔
A
✔
✔
✔
B
✔
✔
C
✔
✔
D
✔
✔
E
✔
✔
✔
F
✔
✔
For L2, make a selection from the table below.
L2
Entry
Arm
Away
Arm
Stay
Pager
Alert/Trouble
0
1
✔
2
✔
3
✔ ✔
4
✔
5
✔ ✔
6
✔ ✔
7
✔ ✔ ✔
Arm Away/Stay: Selects the arming mode that the
designated soft key will activate.
NOTE: If the panel is not ready, the soft key entry will
force-arm the system.
Pager Alert/Trouble: If selected, a message will be sent
to the pager when the designated soft key is pressed. This
can be used to send a “help me” message.
QUESTION 28 AUTO-ARM ENABLES N/U
L1 L2 L3 L4
Q 28, L1–L2 Part 1 Part. 2 Up/About
This question enables auto-arming. See Question 29 (partition 1) and 30 (partition 2) for setting the
auto-arm times for each partition. Enter the L1–L2 digits as follows: