2 www.honeywell.com
PRO3200 Installation
Notices
1  Notices
1.1  Warnings and Cautions 
Note:  See the Remote Enclosure Installation Manuals PPRO22ENC1, PRO22ENC2, 
PRO22ENC3 or PRO22ENC5 for installation instructions.
Before Installation
Warning: Before installation, TURN OFF the external circuit breaker which supplies 
power to the system. 
Before connecting the device to the power supply, verify that the output voltage is 
within specifications of the power supply (see 'Technical Specifications' on page 13).
Do not apply power to the system until after the installation has been completed. 
Personal injury or death can occur, and the equipment can be damaged beyond repair, 
if this precaution is not observed. 
Fire Safety and Liability Notice 
Warning: Never connect card readers to any critical entry, exit door, barrier, elevator or 
gate without providing an alternative exit in accordance with all the fire and 
life safety codes pertinent to the installation. 
These fire and safety codes vary from city to city and you must get approval from 
local fire officials whenever using an electronic product to control a door or other 
barrier. Use of egress buttons, for example, may be illegal in some cities. In most 
applications, single action exit without prior knowledge of what to do is a life safety 
requirement. Always make certain that any required approvals are obtained in writing. 
DO NOT ACCEPT VERBAL APPROVALS SINCE THEY ARE NOT VALID. 
Honeywell never recommends using the PRO3200 or related products for use as a 
primary warning or monitoring system. Primary warning or monitoring systems 
should always meet the local fire and safety code requirements. The installer must also 
test the system on a regular basis by instructing the end user in appropriate daily 
testing procedures. Failure to test a system regularly could make the installer liable for 
damages to the end user if a problem occurs. 
Earth Grounding
Warning: EARTH ground all enclosures for proper installation. 
Use Suppressors
Warning: Use suppressors on all door strikes. Use S-4 suppressors for installation. 
Honeywell recommends only DC strikes.