PX940 Applicator Interface Installation Instructions 7
10 Service
required
Output Goes LOW during every status that keeps the
printer from printing:
Printhead lifted
•Ribbon out
•Media out
General print engine fault
Front arm lifted
Verifier calibration required
Verifier calibration expired
Exceed maximum barcodes
Verifier hardware error
Verifier failure action prompt
11 End print Output Drives an applicator or other external device
requiring synchronization with the print
cycle. Choose between five types of output
signals:
Mode 0: Applicator port is OFF.
Mode 1: Asserted LOW only when media is
moving, otherwise de-asserted HIGH.
Mode 2: Asserted HIGH only when media is
moving, otherwise de-asserted LOW.
Mode3 (Default): Asserted LOW for 20ms
when label has finished printing and
positioned. Not asserted during continuous
printing.
Mode 4: Asserted HIGH for 20 ms when label
has finished printing and positioned. Not
asserted during continuous printing.
12 Media out Output Goes LOW when the printer is out of media.
13 Ribbon out Output Goes LOW when the printer is out of ribbon.
14 Data ready Output Goes LOW when ready to print. De-asserted
HIGH when printing stops after the current
label.
15 Verification
failed
Output
Goes LOW when the printer encounters
Verification failed error.
Goes HIGH when the error is cleared.
Pin Signal Type Description