3. Scan Function
36 ScanPal EDA50 Enterprise Hybrid Device User Guide
Add a prefix and suffix to
make the data string in the
following order:
Prefix
Sign prefix
Barcode data
Suffix
Data processing
settings
Prefix
Sign prefix
Suffix
Parsing the replacement
for prefix and suffix string
Activate Total Freedom
plug-in
Data processing
settings
Data editing plugin
Input the final data as
Android Key Events
Data processing
settings
wedge
Prefix and suffix will be replaced within the string value.
Prefix and suffix parsing
Substring
Replacement
character code
Wedge in form of KeyEvent
\r
13
No
\n
10
Yes
\t
9
Yes
\\
\
No
Changing scan settings
Changes made to the default file apply for all non-document applications.
1. Tap Settings.
2. Tap Scanning.
3. Tap Default.
4. Select Data Processing Settings, Symbology Settings, Decode Settings,
Imager Settings, Trigger Settings or Notification Settings.
5. Modify the setting to meet application needs.