EasyManuals Logo

Honeywell SmartLine ST700 User Manual

Honeywell SmartLine ST700
9 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
November 2018 Quick Start Installation Guide 7
Hazardous Locations Certifications
AGENCY
TYPE OF PROTECTION
FIELD
PARA-
METERS
AMBIENT
TEMP (Ta)
FM
Approvals
TM
Explosionproof:
Class I, Division 1, Groups A, B, C, D;
Dust Ignition Proof:
Class II, III, Division 1, Groups E, F, G;
Class l, Zone 0/1, AEx d IIC Ga/Gb
Class ll, Zone 21, AEx tb IIIC Db T 95
o
C
Note 1
T5: -50 ºC to 85ºC
T6: -50 ºC to 65ºC
Intrinsically Safe:
Class I, II, III, Division 1, Groups A, B,
C, D, E, F, G
Class l, Zone 0, AEx ia IIC Ga
T4: -50 ºC to 70ºC
Nonincendive:
Class I, Division 2, Groups A, B, C, D
Class l, Zone 2, AEx nA IIC Gc
Note 1
T4: -50 ºC to 85ºC
Enclosure: Type 4X/ IP66/ IP67
All
-
Canadian
Standards
Association
(CSA)
Explosion Proof:
Class I, Division 1, Groups A, B, C, D;
Dust Ignition Proof:
Class II, III, Division 1, Groups E, F, G;
Ex d IIC Ga
Ex tb IIIC Db T 95
o
C
Note 1
T5: -50 ºC to 85ºC
T6: -50 ºC to 65ºC
Intrinsically Safe:
Class I, II, III, Division 1, Groups A, B,
C, D, E, F, G
Ex ia IIC Ga
T4: -50 ºC to 70ºC
Nonincendive:
Class I, Division 2, Groups A, B, C, D;
T4
Ex nA IIC Gc T4
Note 1
T4: -50 ºC to 85ºC
Enclosure: Type 4X/ IP66/ IP67
All
-
ATEX
Flameproof:
II 1/2 G Ex d IIC Ga/Gb
II 2 D Ex tb IIIC Db T 95
o
C
Note 1
T5: -50 ºC to 85ºC
T6: -50 ºC to 65ºC
Intrinsically Safe:
II 1 G Ex ia IIC Ga
T4: -50 ºC to 70ºC
Nonincendive:
II 3 G Ex nA IIC Gc
Note 1
T4: -50 ºC to 85ºC
Enclosure: IP66/ IP67
All
-
IECEx
(World)
Flameproof :
Ex d IIC Ga/Gb
Ex tb IIIC Db T 95
o
C
Note 1
T5: -50 ºC to 85ºC
T6: -50 ºC to 65ºC
Intrinsically Safe:
Ex ia IIC Ga
T4: -50 ºC to 70ºC
Nonincendive:
Ex nA IIC Gc
Note 1
T4: -50 ºC to 85ºC
Enclosure: IP66/ IP67
All
-
SAEx
South Africa
Flameproof :
Ex d IIC Ga/Gb T4
Ex tb IIIC Db T 95
o
C
Note 1
-50 ºC to 85ºC
Intrinsically Safe:
Ex ia IIC Ga T4
Note 2a
-50 ºC to 70ºC
Nonincendive:
Ex nA IIC Gc T4
Note 1
-50 ºC to 85ºC
Enclosure: IP66/ IP67
All
-
INMETRO
Brazil
Flameproof:
Ex db IIC T6..T5 Ga/Gb
Ex tb IIIC T 95
o
C Db
Note 1
50 ºC to 85ºC
Intrinsically Safe:
Ex ia IIC T4 Ga
Note
2a
50 ºC to 70ºC
Nonincendive:
Ex nA IIC T4 Gc
Note 1
-50 ºC to 85ºC
Enclosure : IP 66/67
All
-
NEPSI
(China)
Flameproof:
Ex d IIC Ga/Gb
Ex tb IIIC Db T 85
o
C
Note 1
T5: -50 ºC to 85ºC
T6: -50 ºC to 65ºC
Intrinsically Safe:
Ex ia IIC Ga
T4: -50 ºC to 70ºC
Nonincendive:
Ex nA IIC Gc
Note 1
T4: -50 ºC to 85ºC
Enclosure : IP 66/67
All
-
EAC
Russia,
Belarus and
Kazakhstan
Flameproof:
1 Ex d IIC Ga/Gb T4
Ex tb IIIC Db T 85
o
C
Note 1
-50 ºC to 85ºC
Intrinsically Safe:
0 Ex ia IIC Ga T4
Note
2a
-50 ºC to 70ºC
Enclosure : IP 66/67
All
-

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell SmartLine ST700 and is the answer not in the manual?

Honeywell SmartLine ST700 Specifications

General IconGeneral
SeriesSmartLine
ModelST700
Output Signal4-20mA dc, Digital Communication
Process Temperature-40 to 120°C (-40 to 248°F)
Ambient Temperature-40 to 185°F (-40 to 85°C)
Process Connection1/2" NPT, 1/4" NPT
Housing MaterialAluminum or Stainless Steel
ProtectionNEMA 4X, IP66/67
DisplayLCD with backlight, optional
Power Supply10.5 to 45 V DC
Communication ProtocolHART, FOUNDATION Fieldbus
CertificationsATEX, IECEx, CSA

Related product manuals