EasyManua.ls Logo

Honeywell TrolATemp TZ-3 TotalZone User Manual

Honeywell TrolATemp TZ-3 TotalZone
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
PRODUCT DATA
68- 022
3
-
2
® U.S. Re
g
istered Trademark
Co
py
ri
g
ht © 2001 Hone
y
well • All Ri
g
hts Reserved
TZ-3 TotalZone® Zone Control Panel
APPLICATION
The TZ-3 TotalZone Zone Control Panel controls sin
g
le-sta
g
e,
multi-sta
g
e, conventional or heat
p
um
p
heat/cool e
q
ui
p
ment.
It controls 2 or 3 zones, and is ex
p
andable u
p
to 30 zones with
o
p
tional TotalZone® Add-A-Zone™ Zone Control Panel.
FEATURES
Up to three stages heat and two stages cooling can be
controlled by thermostat or built-in timer, based on the
number of zones calling.
Controls up to three zones and can be expanded with
TotalZone Add-A-Zone zone Control Panel for up to 30
zones.
Uses virtually any Honeywell four-wire, single-stage,
multi-stage, or Trol-A-Temp heat pump thermostat.
Zone-A-Lone central setback feature.
Purge timer protects equipment between calls for heat
or cool with choice of continually on or equipment
controlled fan.
System and zone damper LEDs indicate system and
damper status.
Individual zone fan control.
Optional Discharge Air Temperature Sensor for
capacity control with adjustable high and low limits.
Thermal circuit breaker protects panel and transformer
from damage if miswired.
For Internet access: www.trolatem
.com or
www.hone
well.com/
ourhome/zonin
/zonin
_home.htm
For technical su
ort, call 1-800-TAT-Tem
1-800-828-8367
.
To download Zonin
literature: htt
://hbctechlit.hone
well.com
Contents
A
pp
lication.........................................................................1
Features ............................................................................1
S
p
ecifications ....................................................................2
Installation .........................................................................4
Startu
p
and Checkout........................................................9
O
p
eration...........................................................................10
Troubleshootin
g
.................................................................13

Questions and Answers:

Honeywell TrolATemp TZ-3 TotalZone Specifications

General IconGeneral
Power Supply24 VAC
Operating Temperature32°F to 122°F (0°C to 50°C)
CommunicationProprietary
DisplayLCD
Zones SupportedUp to 3

Summary

TZ-3 TotalZone Zone Control Panel

Application Overview

Controls single-stage, multi-stage, conventional or heat pump equipment for 2 or 3 zones.

Key Features

Highlights multi-stage control, zone expansion, and thermostat compatibility.

Specifications and Recommendations

Electrical, Dimensions, and Wiring

Details electrical requirements, physical dimensions, mounting, and wiring specifications.

Recommended Thermostats

Lists compatible thermostat models for various system types.

Recommended Dampers

Specifies damper types and their terminal connections for zone control.

Recommended Dampers and Accessories

Damper Types and Bypass Ratings

Lists Honeywell damper types, their bypass ratings, and applications.

Required Accessories

Details essential accessories like transformers and static pressure regulators.

Installation Procedures

Mounting Guidelines

Provides instructions and cautions for mounting the TZ-3 panel and thermostats.

Wiring Connections

Outlines wiring procedures for thermostats, dampers, sensors, and HVAC equipment.

Wiring Diagrams

Heat Pump Thermostat Wiring

Shows wiring for heat pump thermostats with single Y or Y1/W1 terminals.

Damper Wiring Configurations

Details wiring for AOBD, ARD, ZD, and MARD/CDO-51 dampers.

Wiring Diagrams Continued

Motor Actuator and Transformer Wiring

Illustrates ML6161 actuator wiring and 24V transformer connections.

Discharge Air Temperature Sensor Wiring

Depicts the connection of the DA temperature sensor to the TL terminals.

Equipment Wiring

Multi-Stage Equipment Wiring

Describes wiring for multi-stage heating and cooling equipment.

Heat Pump Equipment Wiring

Details wiring for heat pump systems, including auxiliary heat.

Heat Pump and Water Source Heat Pump Wiring

Heat Pump with Auxiliary Heat

Shows wiring for heat pumps with auxiliary heat systems.

Water Source Heat Pumps

Details wiring for water source heat pumps with specific system configurations.

Startup and Checkout

Initial Setup and Configuration

Guides through initial setup, including switch positions and powering up the TZ-3.

Operation Verification Steps

Describes procedures to verify correct heating, cooling, and damper operation.

Operation Modes

Sequence of Operation

Explains zone control logic for heating, cooling, and purge cycles.

Staging and Fan Control

Details multi-stage operation and individual zone fan control.

Staging and Thermostat Control

Staging Logic and Heat Pump Thermostats

Covers staging based on zone count and heat pump thermostat usage.

Emergency Heat and Multi-Stage Thermostats

Explains emergency heat control and operation with multi-stage thermostats.

Advanced Features and System Protection

Microprocessor Reset and Zone-A-Lone

Instructions for rebooting the microprocessor and operating the Zone-A-Lone feature.

Discharge Air Sensor and Circuit Breaker

Details DA sensor setup and the function of the built-in circuit breaker.

Troubleshooting Guide

Common Symptoms and Resolutions

A table listing common issues, their causes, and recommended actions.

Configuration and Indicators

DIP Switch Settings and Functions

Details the purpose of each DIP switch and its available settings.

LED Indicator Meanings

Explains the status indicated by different LED colors and patterns.

Control Panel Overview

TZ-3 Panel Component Diagram

A detailed diagram showing all terminals, components, and features of the TZ-3 control panel.