Ideal when…
• TrueDRY DR65 will not be ducted to a
forced air HVAC system.
Attach 3/4-in. male NPT drain nozzle.
Connect 1/2-in. drain tube to male connection drain outlet.
Secure drain tube to connector with hose clamp.
Run drain hose continuously downhill to an approved drain or
condensate pump.
The drain line must include a water trap to prevent air from
entering or exiting the dehumidifier.
Plumbing
Install to Fit Your Application (continued)
TrueDRY
RETURN
SUPPLY
TrueDRY™ DR65 Dehumidication System 69-2089EFS—14
6
D
Dedicated Return to Dedicated Supply
SUPPLY
RETURN
Main Return to Main Return
Ideal when…
• Running TrueDRY DR65 with A/C
operation.
• System fan must run with dehumidifier.
• Minimizing discharge air temperature
(DAT) increase is preferred.
• Access to a dedicated central return for
TrueDRY DR65 is not available.