Wiring (continued)
To prevent damage to the 24 volt control transformer, the DR65A2000 comes with a resettable circuit breaker.
Check wiring for any electrical short and repair before resetting breaker. Resetting the circuit breaker without
correcting the electrical short may result in transformer damage. Be sure to check the electrical schematics in
this manual or inside the access panel of the DR65A2000 before making any control connections. The reset
button for the circuit breaker can be found on the back of the unit.
Apply power to TrueDRY DR65. Turn the humidity control to a low RH% level to initiate a dehumidification call.
Confirm that the TrueDRY DR65 compressor and fan turn on. The furnace blower will also turn on to circulate air.
This will take up to two minutes. Be sure to turn the control to the desired RH% or to Off when checkout is com-
plete. Turning the humidity control to Off will turn TrueDRY DR65 off.
Circuit Breaker
Checkout
M33158B
FAN
FURNACE BOARD
EQUIPMENT INTERFACE MODULE (EIM)
G
C
CONV.HP
1
2
3
C
R
RC
RH
W1
W2
W3
Y
Y2
G
O/B
AUX
AUX2
Y
Y2
G
U1
U1
U2
U2
U3
U3
HEAT 1 RELAY
HEAT 2 RELAY
HEAT 3 RELAY
COOL 1 RELAY
COOL 2 RELAY
FAN RELAY
VISIONPRO IAQ
D-1
R-2
C-3
TrueDRY
OR
Gt
+
+
Rf
Gf
EARD8TZ
DHUM
+
+
R
FAN
C
FLOAT
CONFIG FOR
DEHUM
CONFIG FOR
VENT
TrueDRY™ DR65 Dehumidication System 69-2089EFS—14
10
Follow this diagram if using TrueDRY DR65
with a Prestige IAQ or VisionPro IAQ.

Questions and Answers: