Honeywell VisionPRO 8000 - Installer Setup (ISU) Table

Honeywell VisionPRO 8000
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VISIONPRO
®
8000 WITH WI-FI
®
11 33-00096—01
Table 2. Installer Setup (ISU) Table.
ISU
Number
Installer Setup
Name Settings Default
Residential,
Commercial
or Both Notes
101 Application
Residential
Commercial
Residential Both
103 Thermostat Name
[Select Thermostat Name]
Thermostat Both The Web Interface displays the name of the
thermostat that you enter on this screen.
104 Thermostat Type
Non-Programmable
Programmable
Programmable Both
105 Temperature Scale
Fahrenheit
Celsius
Fahrenheit Both
106 Outdoor Temp
Wired/Internet
No
No Both Select Wired/Internet to indicate that you are
going to connect a wired outdoor sensor or
connect to the internet. This will allow you to
configure settings prior to the Internet being
connected.
Select No if you are not going to connect to an
outdoor sensor or the Internet.
200 Heating System
Conv. Forced Air
Heat Pump
Radiant Heat
Other
None (Cool Only)
Conv. Forced Air Both For Dual Fuel, choose Heat Pump.
201 Heating
Equipment
Heat Pump:
Air to Air Heat Pump
Geothermal
Geothermal Radiant
Air to Air Heat Pump Both This ISU is not displayed when ISU 200 Heating
System is set to Conv. Forced Air, Radiant
Heat, Other or None (Cool Only).
See “Geothermal Radiant Heat” beginning on
page 56.
202 Radiant Heat
Stages
0
1
2
Both Select the number of radiant heat stages.
203 Radiant Stage 1
None
U1
Default varies based
on previous
selections
Both This ISU is only displayed when ISU 201
Heating Equipment is Geothermal Radiant.
Geothermal Radiant Heat must be wired to
universal terminal U1.
U1 is a normally open set of dry contacts. U1
requires power from the system transformer or
a separate transformer.
205 Geo Forced Air
None
Cooling Only
Heating and Cooling
Heating and Cooling Both This thermostat has the capability of controlling
Geothermal Radiant Heat, Geothermal Forced
Air and Backup Heat.
If this thermostat is not controlling the
Geothermal Forced Air System, select None.
This setting is typically used if the thermostat is
only controlling Geothermal Radiant Heat.
If this thermostat is using the Geothermal
Forced Air System for cooling and not for
heating, select Cooling Only.
If this thermostat is using the Geothermal
Forced Air System for both heating and cooling,
select Heating and Cooling.
206 Reversing Valve
O (O/B on Cool)
B (O/B on Heat)
O/B on Cool Both Only displayed if the equipment type is Air to Air
Heat Pump, Geothermal or Geothermal Radiant.