VISIONPRO
®
8000 WITH WI-FI
®
33-00096—01 64
• Low Limit Temperature Setting
If the cooling system is used to control humidity while
Dehumidification Away Mode is active, the thermostat
allows the cooling system to lower the indoor air to the
Low Limit Temperature Setting to reach the
Dehumidification Setting at ISU 920.
• Temperature Setting
The temperature maintained while Dehumidification
Away Mode is active and the desired humidity level is
satisfied.
• Dehumidification Setting
The desired humidity level while Dehumidification
Away Mode is active.
Fig. 140.
Control Dehumidification Level
1. Touch MENU and select Dehumidification.
Fig. 141.
Fig. 142.
2. Select Auto.
Fig. 143.
3. Touch or to select humidity level.
4. Touch Done to save your settings. Touch Cancel to
ignore changes.
NOTE: If your air conditioner is used to control humidity,
the temperature may drop up to 3° F below your
temperature setting until humidity reaches the
desired level.
NOTE: If humidification and dehumidification are setup
to operate in the same system mode (Heat, Cool,
Off), the thermostat will automatically enforce a
15% deadband between the humidification and
dehumidification settings. The thermostat will
automatically switch between humidification and
dehumidification to maintain the desired humidity
level.
Dehumidification - Commercial
The thermostat reads the indoor humidity level and allows the
user to set a dehumidification setting. The thermostat controls
the humidity level using the cooling system or a dehumidifier.
If humidification and dehumidification are setup to operate in
the same system mode (Heat, Cool, Off), the thermostat will
automatically enforce a 15% deadband between the
MCR34100
MCR34130
Dehumidification
Equipment Status
MCR34131
Dehumidification
Off Auto