VISIONPRO
®
8000 WITH WI-FI
®
33-00096—01 42
3. Touch Done to save and exit.
On: Fan is always on.
Auto: Fan runs only when heating or cooling system is
on.
Circ: Fan runs randomly, about 35% of the time
(residential only).
Follow Schedule: Fan controlled by program. This
option may not appear, depending on how your fan
was programmed.
Fig. 34.
NOTE: In commercial use, touch Auto or On to temporar-
ily override the programmed fan schedule.
Setting System Mode
1. Touch SYSTEM to display system settings.
Fig. 35.
2. Touch desired option
Heat: Controls only the heating system.
Cool: Controls only the cooling system.
Off: Heating/cooling systems are off.
Auto: Selects heating or cooling depending on the
indoor temperature.
Em Heat (heat pumps with aux. heat): Controls
auxiliary/emergency heat. Compressor is locked out.
Fig. 36.
3. Touch Done to save and exit.
NOTE: The Auto and Em Heat system settings may not
appear, depending on how your thermostat was
installed.
Preset Energy-Saving Schedules
These default Energy Saver settings can reduce expenses.
* Period 2 is cancelled by default. If you activate it, the values
shown above are default settings.
Adjusting Program Schedules
1. Touch MENU.
Fig. 37.
2. Select Edit Schedule to display Use Scheduling Assis-
tant?
Fig. 38.
Touch Yes to create a schedule by answering simple
questions.
Touch No to manually create a program schedule.
Fig. 39.
MCR34097
On Auto Circ
MCR34098
MCR34099
Heat Cool Auto
Off
Table 3. Residential Use Default Schedule.
Period
Start
Time
Heat
(Mon-Fri)
Cool
(Mon-Fri)
Heat
(Sat-Sun)
Cool
(Sat-Sun)
Wake 6:00 am 70° 78° 70° 78°
Leave 8:00 am 62° 85° 62° 85°
Return 6:00 pm 70° 78° 70° 78°
Sleep 10:00 pm 62° 82° 62° 82°
Table 4. Commercial Use Default Schedule.
Period Start Time Heat Cool Fan
Occupied 1 8:00 am 70° 7 On
Unoccupied 1 10:00 pm 55° 85° Auto
Occupied 2* 12:00 am 70° 75° On
Unoccupied 2* 12:00 am 55° 85° Auto
MCR34100