The CAFP100FxxFRTadopts an intelligent power management system and supports such functions as
timingpoweron/shutdownandsleeptiming.
1)PowerOn
ThisoptionisusedtoautomaticallypowerontheFRTatspecifiedtime.Thesettingsoftimingpoweronare
similartothoseoftimi ngpoweroff.
2)Sleep
ThisoptionisusedtosettheFRTtoautomaticallyentersleepmodeatspecifiedtime.Youcanwakeupthe
FRTfromsleepmodebypressinganykey.Thesettingstepsofthisparameteraresimilarwiththoseoftiming
shutdo wn.
4)Idle&IdleTime
Thesetwooptionsareclosel yassoci ated.WhenIdleminis0,theIdlefunctionisdisabled.WhenIdleminisa
nonzeronumber(unit:minute),forexample,1,thesystemwillenteraspecifiedstateifthereisnooperation
in1minute.
4.3Communicatio nrelatedSettings
SelectComm.Optandtheinformationdisplayedonthescreenisshowninthefollowingfi gure:
CommOpt ▼
►BaudRate 115200
DevNo. 1
NetSpeed Auto
IPAddr 192.168.1.201
NetMask
255.255.255.0
Gateway 192.168.1.1
Ethernet Y
RS232 N
RS485 N
COMMKey 0
1.BaudRate
ThisoptionisusedtosetthebaudrateforthecommunicationbetweentheFRTandthePC.Itincludesfive
options: 9600, 19200, 38400, 57600, and 115200. The high baud rate is recommended for the RS232
communication to achieve high communication speed, while the low baud rate is recommended for the
RS485communicationtoachievestablelowspeedco mmunication.
2.DevNo.
ThisoptionreferstothedeviceIDnumberedfrom1to255.
3.NetSpeedê
Thisparameterreferstothenetworkrate,includingfiveoptions:ATUO,10MF,10MH,100MFand100MH.
"10MF" is recommended for the ZEM100 product series and "AUTO" is recommended for the ZEM200
productseries.
4.IPAddrê
ThedefaultIPaddressis192.168.1.201.YoucanmodifytheIPaddressasrequired.
5.NetMaskê
Thedefaultsubnetmaskis255.255.255.0.Youcanmodifythesubnetaddressasrequired.
6.Gatewayê
Thedefaultgatewayis0.0.0.0.Youcanmodifythegatewayasrequi red.
7.Ethernetê
ThisparameterisusedtosetwhethertoadopttheEthernetforcommunications.ToadopttheEthernet,set
thisparametertoY;otherwisesetittoN.
8.RS232