12 - 5
*Storage outside of this temperature range could be detrimental to battery life.
Image Size 838 x 640 pixels
Skew Angle +
65°
Pitch Angle +
45°
Motion Tolerance:
Streaming Presentation Trigger:
13 mil UPC
240 inches per second at 6.5 in. (16.5cm)
150 inches per second at 10 in. (25.4cm)
Symbol Contrast Grade 1.0 (20% or greater)
Battery:
Lithium Ion
1800 mAHr minimum
Number of Scans Up to 50,000 per charge
Expected Hours of Operation 14
Expected Charge Time 4.5 hours
Radio:
Frequency
2.4 to 2.5 GHz (ISM Band) Frequency Hopping
Bluetooth v.2.1
Range
330 ft. (100m) typical
Data Rate
Up to 1 MBps
Temperature Ranges:
Operating while not charging
-4°F to + 122°F (-20°C to 50°C)
Operating while charging
41°F to + 104°F (5°C to 40°C)
Storage*
-40°F to +158°F (-40°C to 70°C)
Humidity Up to 95% non-condensing
Mechanical Drop
Operational after 50 drops from 6.5 feet
(1.98m) to concrete at 23°, -30°, and 50°C
Vibration
Complies with MIL-STD-810G, Method 514.6, Annex
C
ESD Sensitivity
Up to 20kV direct air
Up to 8 kV indirect coupling plane
Sealant Rating IP65
Parameter Specification

Table of Contents

Other manuals for Honeywell XENON 1902