124 Xenon/Granit User Guide
piness is decreased, making it less aggressive when reading good quality bar 
codes. This setting does not affect 1D bar code reading. Default = Poor Quality PDF 
Reading Off.
CodeGate
®
When CodeGate is On, the trigger is used to allow decoded data to be transmitted 
to the host system. The scanner remains on, scanning and decoding bar codes, but 
the bar code data is not transmitted until the trigger is pressed. When CodeGate is 
Off, bar code data is transmitted when it is decoded. Default = CodeGate Off Out-of-
Stand.
Streaming Presentation™ Mode
When in Streaming Presentation mode, the scanner’s aimer goes out after a short 
time, but the scan illumination remains on all the time to continuously search for 
bar codes. Two modes are available, Normal and Enhanced. Normal mode offers 
good scan speed and the longest working ranges (depth of field). Enhanced mode 
will give you the highest possible scan speed but slightly less range than Normal 
mode. Enhanced mode is best used when you require a very fast scan speed and 
don’t require a long working range.
Note: Granit 1980i and 1981i do not support Enhanced Streaming Presentation Mode. 
Poor Quality PDF Reading On
* Poor Quality PDF Reading 
Off
* CodeGate Off
Out-of-Stand