- 66 -
Access to the oven:
All ovens Distance measured in mm
Left side minimum 50 mm (2”)
Rear side minimum 50 mm (2”)
Right side minimum 400 mm (15”)
Drain connection:
Heat-resistant drain tube connected.
Fall of at least 3º or 5%.
CombiPlus fitted with open drain for both ovens.
The drain must never end directly beneath the oven.
Voltage and water supply:
(Please insert the measured value)
Voltage measured at:
Water pressure measured at: (min. 2 bar/28,5 psi max. 6 bar/88
psi).
Does the voltage on site comply with the voltage stated on the
approval plate?
Dirt filter fitted.
Function test:
All electrical connections are tight.
All water connections are tight and have been fastened.
All functions are operable.
All equipment is operable.
Yes No
Yes No
Yes No