Loading...
10
FieldInstallation
Evacuation
Donotusetherefrigerationcompressorto
evacuatethesystem.Donotstartthe
compressorwhileitisinavacuum.
Agood,deepvacuumpumpshouldbe
connectedtoboththelowandhighside
evacuationvalveswithcoppertubeorhigh
vacuumhoses(1/4”IDminimum).
Ifthecompressor
hasservicevalves,they
shouldremainclosed.
Adeepvacuumgaugecapableofregistering
pressureinmicronsshouldbeattachedtothe
systemforpressurereadings.
Ashutoffvalvebetweenthegaugeconnection
andvacuumpumpshouldbeprovidedtoallow
thesystempressuretobecheckedafter
evacuation.
Donotturnoffvacuumpumpwhenconnected
toanevacuatedsystembeforeclosingshutoff
valve.
Thevacuumpumpshouldbeoperateduntila
pressureof1,500micronsabsolutepressureis
reachedatwhichtimethevacuumshouldbe
brokenwiththerefrigeranttobeusedinthe
system
throughadrieruntilthesystem
pressurerisesabove“0”psig.
Refrigerantusedduringevacuationcannotbe
vented.Reclaimallusedrefrigerant.
Repeatthisoperationasecondtime.
Openthecompressorservicevalvesand
evacuatetheentiresystemto500microns
absolutepressure.Raisethepressureto2psig
with
therefrigerantandremovethevacuum
pump.
FieldWiring
Allfieldwiringmustbeincompliancewithlocal
andnationalcodes.Useonlycopper
conductorsoftheappropriatesize.
1. Installdisconnect(notsuppliedby
factory).
2. Connect208230/1/60powertothe
twoblackwiresmarked“L1”and“L2”
inthejunctionboxontherearofthe
IceFlaker.
3. Inthejunctionboxtherearetwored
wiresmarked“A”and“B”.Remove
wirenut.
4. Connectthenormallyopenisolating
contactsfromtherelaymountedinthe
condensingunitto“A”and“B”.

5. LocateandconnectPhotoEyesensors
tothematchingplug
insidetheIce
Flakerenclosure(seep.24).