FieldInstallation
InstallationChecklist
1. Hastheambienttemperaturebeenverifiedbetween50°F–100°F?
(seeLocationRequirements p.3)
2. Hastheincomingwatertemperaturebeenverifiedbetween45°F–90°F?
(seeWaterSupplyRequirementsp.3)
3. Hasthewatersupplypressurebeenverifiedbetween20PSIGand60PSIG?
(seeWaterSupplyRequirements
p.3)
4. HasthefilteredwatersupplybeenverifiedasnotROwater?
(seeWaterSupplyRequirementsp.3)
5. HastheIceFlakerbeenlocatednearafloorsanitarysewerdrain?
(seeDrainWaterPipingRequirementsp.4)
6. HavetheEPRandSuctionLineHeatExchangerbeeninstalledcorrectly?
(seeSuggested
RefrigerantPipingDiagramp.6)
7. Havealltherefrigerationlinesbeensufficientlyinsulated?
(seeRefrigerantPipeworkInsulationRequirementsp.7)
8. HastheCondensingUnitbeenmountedproperly?
(seeCondensingUnitRiggingandMountingp.8)
9. Hasthesystembeenleaktestedproperly?
(seeLeakTestingp.9)
10. Hasthesystem
beenevacuatedproperly?
(seeEvacuationp.10)
11. HavethePhotoEyesensorsbeenconnected?
(seeFieldWiringp.10)
12. Hasthesystembeenchargedproperly?
(seeRefrigerantChargingInstructionsp.11)