EasyManua.ls Logo

Howe 2000-RLE - Refrigeration Requirements

Default Icon
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EngineeringGuidelines
5
RefrigerationRequirements
Model RefrigerationRequirements* OptimumEvaporatorTemperature
1000‐RLE 9,500BTU/hr 0°F
2000‐RLE 18,000BTU/hr‐5°F
3000‐RLE 27,000BTU/hr‐5°F
*RefrigerationrequirementsarebasedonoperatingtheIceFlakerwith70°Fsupplywaterand90°Fambientairconditions.
Refrigerationrequirementsand/orcapacitywillvarywithtemperaturesoutsidetheseconditions.
HoweFurnishedCondensingUnits
Howefurnishedcondensingunitsareproperly
sizedforoutdoordesignambienttemperature
andsupplywatertemperatureconditions.
Thesecondensingunitsarefactoryequipped
withthefollowingaccessories:
LiquidLineFilter/DrierandSightGlass
SuctionFilter
SuctionAccumulator
OilSeparator
RefrigerantPump‐Down
Cycle
HeatedandInsulatedReceiver(except
forhighambientapplications)
DiscusCompressor
CondenserFanCyclingcontrol
Non‐AdjustableHeadPressureControl
Valve
FieldFurnishedCondensingUnits
Howeisnotresponsiblefortheperformanceof
fieldfurnishedcondensingunits.Howe
recommendsfieldfurnished condensingunits
besized
withsufficientrefrigerationcapacityat
thelocaldesignoutdoorambienttemperature
includingenoughsystemcapacitytooffset
suctionlinepressurelosses.Howealso
recommendsfieldfurnished condensingunits
beatleastequippedwiththeaccessories
outlinedintheprevioussectiontoensure
successfuloperationoftheIceFlaker.