32
Maintenance
CleaningProcedure
Tokeeptheevaporatorinpeakperformance,
theIceFlakershouldbecleanedevery6months
ormoreoftenifwaterconditionsdictate.
Onlyusecleaningsolutionsthatarelabeledas
“Nickel‐Safe”.
1. TurnthePowerSwitch“Off”attheIce
FlakerControlPanel.
2. OpenIceFlakerControl
Panelandturn
Off‐Delaytimerknobfullyclockwiseto
30minutesruntime.
3. RemoveallicefromIceBin.
4. Closewatersupplyatshut‐offvalve.
5. OpenIceFlakerStopValvetoallow
watertoexitfromWaterSump.
AfterwardscloseStopValveto
prevent
lossofsolution.
6. Prepareapprovedcleaningsolutionby
followingmanufacturer’sinstructions.