37
Troubleshooting
(Note:Allwirecolorsaresubjecttochange)
Problem PossibleCause PossibleSolution
IceFlakerwillnotrun
1. UnpluggedordefectivePhotoEye(s). 1. EnsureMolexplugsareproperlyandsecurelyconnected.Placeawirejumper
betweenterminals#10(blue)and#11(black)attheLevelControlRelay(LC1).IfIce
Flakerstarts,PhotoEyesmaybedefectiveandneedtobereplaced.
2. DefectiveLevelControlRelay(LC1). 2. Placeawirejumperbetweenterminals#5(red)and#6(red)attheLevelControl
Relay(LC1).IfIceFlakerstarts,LevelControlRelay(LC1)maybedefectiveand
needtobereplaced.
3. NocontrolpowerfromTransformer(T1). 3. CheckvoltageacrossTerm1(purple)andTerm2(yellow/orange)atControl
Module(CM).If24VACnotpresent,Transformer(T1)maybedefectiveandneed
tobereplaced.
4. Openswitchorloosewiring. 4. PlaceawirejumperbetweenTerm2(yellow/orange)andTerm3(red)atControl
Module(CM).IfIceFlakerstarts,tracevoltagefromTerm3.Checkallwire
terminalsandtightenasnecessary.
5. DefectiveControlModule(CM). 5. PlaceawirejumperbetweenTerm2(yellow/orange)andTerm3(red)atControl
Module(CM).IfIceFlakerdoesnotstart,ControlModule(CM)maybedefective
andneedtobereplaced.
IceFlakerdoesnot
shutdownwhen
IceBinisfull
1. DefectiveEmitterPhotoEye. 1. UnplugEmitterPhotoEyeandwaitlongerthanOff‐Delaysetting.IfIceFlaker
stops,EmitterPhotoEyemaybedefectiveandneedtobereplaced.
2. DefectiveReceiverPhotoEye. 2. UnplugReceiverPhotoEyeandwaitlongerthanOff‐Delaysetting. IfIceFlaker
stops,ReceiverPhotoEyemaybedefectiveandneedtobereplaced.
3. LevelControlRelay(LC1)isjumpedout. 3. Checkforawirejumperbetweenterminals#5(red)and#6(blue)atLevelControl
Relay(LC1).Ifpresentremovewirejumper.
4. DefectiveControlModule(CM). 4. RemovewirefromTerm3(red)atControlModule(CM)andwaitlongerthanOff‐
Delaysetting.IfIceFlakerdoesnotstop,ControlModule(CM)maybedefective
andneedtobereplaced.
SolenoidValvewillnotopen
1. DefectiveControlModule(CM). 1. Verify24VACpresentacrossTerm1(purple)andTerm3(red)atControlModule
(CM).RemovewiresandcheckforcontinuitybetweenTerm7(black)andTerm8
(red).Ifthecontactsremainopen,ControlModule(CM)maybe
defectiveand
needtobereplaced.
2. DefectiveSolenoidValve. 2. VerifycontrolvoltageatSolenoidValvewireleads.Ifvoltageispresent,Solenoid
Valvemaybedefectiveandneedtobereplaced.
3. DefectiveMotorRelay(R1). 3. Placeawirejumperbetweenterminals#6(yellow)and#7(black)atMotorRelay
(R1).IfSolenoidValveopens,MotorRelay(R1)maybedefectiveandneedtobe
replaced.
4. Loosewiring. 4. Checkallwireterminalsandtightenasnecessary.