EngineeringGuidelines
3
EngineeringGuidelines
LocationRequirements
HoweRapidFreezeIceFlakersaredesignedto
operateinambientroomtemperatures
between50°Fand100°F.
MinimumAmbient
Temperature
MaximumAmbient
Temperature
50°F 100°F
TheIceFlakerwarrantyisvoidifitisinstalled
inambientroomtemperaturesbelow50°F.
TheIceFlakermustbelocatedaboveasanitary
sewerfloordrainhubortrenchdraintoensure
properdrainagetothefloor.Manydesigners
slopefloorstothesanitarysewerinletsto
manage
thesewetareas.
IfinstallingtheIceFlakerwithaHoweIceBin,
ensurethatthebinisadequatelysecuredtothe
floorsoastopreventtheassemblyfromtipping
whenempty.
WaterSupplyRequirements
ColdwatersupplytotheIceFlakermustbe
totallyseparateandunaffectedbyanylocalhot
watersupply.
Thiscoldwatersupplymustbewithintherange
of45°Fto90°F.
MinimumWater
SupplyTemp.
MaximumWater
SupplyTemp.
45°F 90°F
Thecoldwatersupplypressuremustbewithin
a20PSIGto60PSIGrange.
MinimumWater
Pressure
MaximumWater
Pressure
20PSIG 60PSIG
StraightReverseOsmosis(RO)treatedwater
shouldneverbesuppliedtotheIceFlaker.
ROsystemtreatedwaterisaggressivetoward
metalsandplatedsurfaces.InadditionRO
waterwillaffectthelifeandintegrityofrubber
andplasticmaterialIceFlakercomponents.If
onlyROwaterisavailable,Post‐
ROtreatment
mustbeprovidedtoraisepHandmineral
content.
Generally,filtrationofcoldsupplywateris
recommended.Howeoffersacompletelineof
replaceablecorecartridgefiltertreatment
systemsdesignedtoimproveicequalityand
extendthelifeoftheIceFlaker.
THEINFORMATIONFOUNDINTHISMANUALISINTENDEDFORUSEBYINDIVIDUALSPOSSESSING
EXPERIENCEDBACKGROUNDSINELECTRICAL,REFRIGERATIONANDMECHANICALREPAIRAND
MAINTENANCE.ANYATTEMPTTOREPAIRORALTERTHISEQUIPMENTMAYRESULTINPERSONAL
INJURYORPROPERTYDAMAGE.THEMANUFACTURERISNOTRESPONSIBLEFORTHEINTERPRETATION
OFTHEINFORMATIONCONTAINED
HEREIN,NORHASTHEMANUFACTURERASSUMEDANYLIABILITYIN
CONNECTIONWITHITSUSE.
THEMANUFACTURERISNOTRESPONSIBLEFORANYLOSS,DAMAGEORINJURYCAUSEDASARESULT
OFEITHER(I)ANYREPAIRORREPLACEMENTTOTHEMANUFACTURER’SEQUIPMENTTHATISDONEBY
ATHIRDPARTYNOTPREVIOUSLYAPPROVEDBY
THEMANUFACTURER,OR(II)ANYREPAIRORSERVICE
WORKPERFORMEDONANYOFTHEMANUFACTURER’SEQUIPMENTWHICHDOESNOTSTRICTLY
FOLLOWTHEPROCEDURESSETFORTHHEREIN.
IMPORTANT