20
StartUp&Operation
FieldCapacityCheck
TheIceFlakerisacontinuousproduction
machineandmakesiceatasteadyrateonce
stabilized.
ACapacityCheckconfirmstheIceFlakerand
refrigerationsettingsarecorrect.
1. Chooseanappropriatelysizedcontainer
andweighitwhileempty.
ContainerWeight Lbs.
2. RuntheIceFlakerfor10minutes.
3. Positionthecontainerbelowthe
openingoftheIceFlaker.
4. Catchthefallingiceinthecontainerfor
exactly15minutes.Be surethatthe
containercatchesalloftheice.
5. Weightheiceandthecont ainer
togetherin
poundsusinganaccurate
scale.Donotdrainbeforeweighing.
MeasuredWeight Lbs.
6. Subtracttheweightofthecontainer.
MeasuredWeight
(from#5)
‐ContainerWeight‐
(from#1)
=CalculatedWeight = Lbs.
7. Calculatethecapacitybymultiplying
thecalculatedweightby96.
CalculatedWeight
(from#6)
x96 x96
=Capacity = Lbs.per
24hrs.
8. Comparethenumberwiththerated
capacityoftheIceFlaker.Keepinmind
temperaturesoutsidetherated
conditionswillhaveaneffectonthe
capacity.