168
S:\HP8924C\USRGUIDE\BOOK\chapters\hpibstat.fb
Chapter 4, Status Reporting
Status Reporting
Table 13 Hardware 2 Status Register Group Bit Assignments
Bit
Number
Is Condition
Register
Implemented?
Condition/Event Comment
15 Not Used (Always 0) Defined by SCPI Version 1994.0
14 Unused in Test Set
13 Unused in Test Set
12 Unused in Test Set
11 YES Inconsistent ACP Channel Bandwidth
and Resolution Bandwidth
10 YES ACP Channel Bandwidth or Channel
Offset too wide
9 YES AFGen1 Frequency Exceeds Variable
Frequency Notch Filter Range
8 YES Requested Audio Voltage Too Large for
AFGen2
7 YES Requested FM Deviation Too Large for
RF Generator Frequency
6 YES Requested Simultaneous AM and
FM Modulation
Simultaneous AM and FM Modu-
lation not allowed.
5 YES Audio Input Level Auto Ranging Error
4 YES RF Input Level Auto Ranging Error
3 YES RF Input Frequency Auto Tuning Error
2 YES RF Gen/RF Anal/RF Offset Frequency
Combination Not Possible
(RF GenTune Freq) - (RF Anal
Tune Freq) not equal to (RF Offset
Freq)
1 YES RF Generator Amplitude Level Too
High For Selected Output Port
0 YES Spectrum Analyzer Reference Level Too
High/Low For Selected Input Port