EasyManua.ls Logo

HP 8924C - Serial I;O from IBASIC Programs

HP 8924C
350 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
282
S:\HP8924C\USRGUIDE\BOOK\CHAPTERS\ibasic.fb
Chapter 6, IBASIC Controller
Serial I/O from IBASIC Programs
Serial I/O from IBASIC Programs
There are two serial ports available for I/O (input / output) to peripherals external
to the Test Set. To bring data in to the Test Set through the serial port(s) use the
IBASIC ENTER command. To send data out, use the OUTPUT command.
Serial Ports 9 and 10
The Test Set uses a small RJ-11 female connector on the rear panel for connecting
to the two serial ports. This connector has six wires, 3 for Serial Port Address 9
and 3 for Serial Port Address 10. For information about serial port configuration,
refer to the
"Test Set Serial Port Configuration" on page 246. For connection
information, refer to
figure 37 on page 250.
Before using either port, the RS-232 protocol must be established by setting baud
rate, pacing, and the other settings as explained in
"Test Set Serial Port
Configuration" on page 246
. Functionally, from an I/O perspective, the two serial
ports are identical. However, operationally there is one major difference. The
Serial Port Address 9 settings are adjustable on the I/O CONFIGURE screen or
with IBASIC commands, while the Serial Port 10 settings are adjustable only with
IBASIC commands. There is no screen for Serial Port 10 settings. For more
information, see the CONFigure:SPORt” and “CONFigure:SPB” subsystems in
the HP-IB Command Syntax chapter of the HP 8924C Condensed Programming
Reference Guide which gives the command syntax for Serial Port 9 and 10.