2: System level
Parameters
period-value: Errored frame event detection interval, ranging from 1 to 60 (in seconds).
Description
Use the oam errored-frame period command to set the errored frame event detection interval.
Use the undo oam errored-frame period command to restore the default.
By default, the errored frame event detection interval is one second.
Related commands: oam errored-frame threshold, display oam link-event, and display oam
configuration.
Examples
# Set the errored frame event detection interval to 10 seconds.
<Sysname> system-view
[Sysname] oam errored-frame period 10
oam errored-frame threshold
Syntax
oam errored-frame threshold threshold-value
undo oam errored-frame threshold
View
System view
Default level
2: System level
Parameters
threshold-value: Errored frame event triggering threshold, ranging from 0 to 4294967295.
Description
Use the oam errored-frame threshold command to set the errored frame event triggering threshold.
Use the undo oam errored-frame threshold command to restore the default.
By default, the errored frame event triggering threshold is 1.
Related commands: oam errored-frame period, display oam link-event, and display oam configuration.
Examples
# Set the errored frame event triggering threshold to 100.
<Sysname> system-view
[Sysname] oam errored-frame threshold 100
oam errored-frame-period period
Syntax
oam errored-frame-period period period-value
11

Other manuals for HP A3100-8 v2 SI

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP A3100-8 v2 SI and is the answer not in the manual?

HP A3100-8 v2 SI Specifications

General IconGeneral
BrandHP
ModelA3100-8 v2 SI
CategorySwitch
LanguageEnglish

Related product manuals