Figure 10 IOX Resources Option
5. Select the I/O bay.
6. Click Apply to commit your configuration changes.
To cancel an operation, navigate away from the Modify nPartition screen.
The blades and I/O bay are assigned to the nPartition.
Removing blades and I/O bays from an nPartition
This section describes the procedure to unassign or remove blades and I/O bays from an nPartition.
Removing blades and I/O bays from an nPartition using the OA CLI
Use the following command to remove a blade in enclosure 1 slot 3 from the existing nPartition
2:
parmodify -p 2 -d blade:1/3
For example, the following command deletes I/O bay 1 in enclosure 6 to the existing nPartition
2:
parmodify -p 2 -d io:6/1
NOTE: If the nPartition is active, the blades and I/O bays are unassigned when the nPartition
reboots.
Removing blades and I/O bays from an nPartition 45