37
HP ProCurve ONE Services zl Module (J9289A)
Description
Part of the HP ProCurve Open Network Ecosystem (ONE) program that enables secure best-in-class 
applications and services in the ProCurve infrastructure, the HP ProCurve ONE Services zl Module is an x86-
based server module that provides two 10-GbE network links into the switch backplane and contains a 255 
MB 7200 rpm SATA hard disk drive. Coupled with ProCurve certified services/applications that can take 
advantage of a switch-targeted API for better performance, this module creates a virtual appliance within a zl 
switch slot to provide solutions for business needs, such as network security. The HP ProCurve ONE Services zl 
Module can be moved to any zl switch in the environment.
Consult the HP ProCurve website for applications available for use with the HP ProCurve ONE Services zl 
Module and for information concerning the HP ProCurve ONE program.
Up to four modules can be installed in a single chassis, and a redundant WES Module (J9052A) version 
automatically adopts radio ports if the primary module is unavailable or should fail.
HP ProCurve radio ports supported (ordered separately)
•J9004AHPProCurveRadioPort210(singleIEEE802.11gradio)Integratedantenna
•J9006AHPProCurveRadioPort230(dualradioa+b/g)Integratedantenna
•J9005AHPProCurveRadioPort220(dualradioa+b/g)Plenumrated,externalantennasrequired
NOTE
HP ProCurve Redundant Wireless Services zl Module (J9052A) provides redundancy.
HP ProCurve Threat Management Services zl Module (J9155A) 
HP ProCurve Threat Management Services zl Module with 1-year IDS/IPS subscription (J9156A)
Description
The HP ProCurve Threat Management Services (TMS) zl Module is a multifunction security system for the Switch 
5400zl and 8200zl series. It consists of a stateful firewall, intrusion detection/prevention system (IDS/IPS), and 
VPN concentrator.
Consult the HP ProCurve website for information concerning the HP ProCurve Threat Management Services zl 
Module.
NOTE
Use of the HP ProCurve ONE Services zl Module restricts the temperature specification for the 5400zl series 
switch to 50°C if all installed modules are on the left side of the chassis. If any installed module is on the right 
side of the chassis, the temperature specification of the entire switch is limited to 40°C.
The HP ProCurve ONE Services zl Module can only be used with certified OA services applications. It does not 
support a general application environment.