Diagnostic tools and setup utilities 110
POST error indicators
When POST detects a system failure, it displays a POST error message.
POST errors Message Definition
When a non-fatal error occurs during POST, the screen will display an error message with the format
“xxx-Error Identifier String” where “xxx” is a unique number code that matches ODM system specific
error documentation and may be a hexadecimal or decimal value.
All Error messages describe the problems as shown below:
Table 19 POST Error Messages
Error code Description
601 Error: BMC Not Responding
605 BMC Has Detected Fatal Hardware Error
611 Internal User Area Of BMC FRU Corrupted
612 Controller Update 'boot block' Firmware Corrupted
613 Controller Operational Firmware Corrupted
624 Power Supply Failure or Power Supply Unplugged
622 Either Fan Failure or Fan Missing
194 CPUID, Processor family are different
192 L3 cache size mismatch
197 Processor speeds mismatched
005 CMOS Checksum Bad
041 Display memory test failed
040 Refresh timer test failed
048 Password check failed
003 CMOS Battery Low
701
Insufficient Runtime space for MPS data.!!.
System may operate in PIC or Non-MPS mode.
702
No enough APIC ID in range 0-0Fh can be assigned to IO APICs.
(Re-assigning CPUs' local APIC ID may solve this issue)
MPS Table is not built! System may operate in PIC or Non-MPS mode.
120 $A0CCMOS Cleared by Jumper. Restore the Jumper and Continue…
122 $A0CPassword Cleared By Jumper. Restore the Jumper and Continue…
POST related troubleshooting
Perform the following procedures when POST fails to run, displays error messages.