Removal and Replacement Procedures
Powering Down the Server
The server does not completely power down when the front panel power button is pressed.
The button toggles server power between On and Standby. In Standby, the server removes
power from most electronics and drives, portions of the power supply and some internal
circuitry remain active. To completely remove all power from the system, disconnect the
power cord from the server.
WARNING: To reduce the risk of injury from electric shock, remove the power cord to
completely disconnect power from the system.
WARNING: To reduce the risk of personal injury or damage to the equipment, be sure
that only one component is extended at a time. A rack may become unstable if more
than one component is extended for any reason.
WARNING: Because the rack allows you to stack computer components in a vertical
rather than a horizontal plane, you must take precautions to provide for rack stability
and safety to protect both personnel and property. Heed all cautions and warnings
throughout the installation instructions that come with the server.
WARNING: To reduce the risk of personal injury or damage to the equipment, place the
server on a sturdy table or workbench whenever it is removed from the rack for device
accessibility. Refer to the HP ProLiant DL320 Generation 2 Server Setup and
Installation Guide for further information on working with racks.
CAUTION: Moving the Power On/Off switch to the Off position does not completely remove
system power. Some portions of the power supply and some internal circuitry remain active.
Disconnect all power cords from the server to remove all power from the system.
CAUTION: Electrostatic discharge (ESD) can damage electronic components. Be sure you
are properly grounded before beginning any installation procedure. For more information, see
“Electrostatic Discharge Information” in this chapter.
NOTE: Microsoft Windows NT® users may use the Power Down Manager to power down the server.
For information on this system utility, refer to the NTREADME.HLP file on Diskette 1 of the NT Software
Support Diskettes.
HP ProLiant DL320 Generation 2 Server Maintenance and Service Guide 2-5
HP CONFIDENTIAL Codename: Moonstar 266 Part Number: 293164-002 Last Saved On: 4/14/03 9:37 AM

Table of Contents

Other manuals for HP ProLiant DL320

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant DL320 and is the answer not in the manual?

HP ProLiant DL320 Specifications

General IconGeneral
Product LineProLiant
CPU TypeIntel Xeon
StorageUp to 4 LFF (3.5") or 8 SFF (2.5") SAS/SATA/SSD drives (depending on model and configuration)
NetworkEmbedded 1GbE
Power SupplySingle or Redundant Power Supplies (depending on model and configuration)
Form Factor1U
Server TypeRack Server

Related product manuals