10SFF NVMe/SAS backplane option device bay numbering
When the 10SFF NVMe/SAS backplane option is installed, NVMe drives must be installed in bays 9 and
10.The other bays support a mix of NVMe and SAS drives.
Optional rear device bay numbering
The optional rear device bay supports either 1 SFF drive in a SmartDrive carrier, or 2 uFF M.2 drives in an
HPE Smart Carrier M.2 (SCM).
When the HPE SFF Flash Adapter is installed, the uFF drives are recognized as 1 and 101.
Hot-plug drive LED definitions
Item LED Status Definition
1 Locate Solid blue The drive is being identified by a host
application.
Flashing blue The drive carrier firmware is being updated or
requires an update.
2 Activity ring Rotating green Drive activity.
Off No drive activity.
3 Do not remove Solid white Do not remove the drive. Removing the drive
causes one or more of the logical drives to fail.
Table Continued
Hot-plug drive LED definitions 19