EasyManua.ls Logo

HP ProLiant DL360 Gen10 - Uff Drive Components and Leds

HP ProLiant DL360 Gen10
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Drive status LED
Solid green = The drive is a member of one or more logical drives.
Flashing green = The drive is rebuilding or performing a RAID
migration, stripe size migration, capacity expansion, or logical drive
extension, or is erasing.
Flashing amber/green = The drive is a member of one or more
logical drives and predicts the drive will fail.
Flashing amber = The drive is not configured and predicts the drive
will fail.
Solid amber = The drive has failed.
Off = The drive is not configured by a RAID controller.
4 Do Not Remove LED
Solid white = Do not remove the drive. Drive must be ejected from
the PCIe bus prior to removal.
Flashing white = Ejection request pending
Off = Drive has been ejected
5 Power LED
Solid green = Do not remove the drive. Drive must be ejected from
the PCIe bus prior to removal.
Flashing green = Ejection request pending
Off = Drive has been ejected
6 Power button
Press to request PCIe ejection. Removal request can be denied by
the:
RAID controller (one or more of the logical drives could fail)
Operating system
7 Do not remove button Press to open the release lever.
uFF drive components and LEDs
uFF drive components and LEDs 21

Table of Contents

Other manuals for HP ProLiant DL360 Gen10

Related product manuals