To Previous Page IconTo Previous Page
Loading...
Cabling 73
8.
Clip the cable to the power supply air baffle when routing it along the edge of the system board.
9. Coil the cables behind the hard drive backplane to minimize airflow impact.
10. Install the access panel (on page 23).
11. Install the server into the rack ("Installing the server into the rack" on page 31).
12. Remove any installed hard drives.
13. Install a SATA hard drive in hard drive bay 1 ("Installing a hot-plug hard drive" on page 48).
14. Install hard drive blanks in any empty hard drive bays.
15. Connect each power cord to the server.
16. Connect each power cord to the power source.
17. Power up the server (on page 20).
18. Using the HP ROM-Based Setup Utility (on page 80), disable the embedded P420i SAS storage
controller, if necessary.