EasyManua.ls Logo

HP PROLIANT ML350 G6

HP PROLIANT ML350 G6
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware options installation 59
8. Connect the SAS cables to the optional SAS controller or optional SAS expander.
9. Install any hard drives or blanks ("SAS or SATA hard drive option" on page 52).
10. Install the access panel (on page 27).
11. Do one of the following:
o Close or install the tower bezel, as needed.
o Slide the server back into the rack.
12. Power up the server (on page 24).
Two-bay LFF drive cage option
CAUTION: To avoid damage to the pin connectors, install only supported hard drive cages and
components in HP ProLiant ML350 G6 Servers. For supported options, see the QuickSpecs at the
HP website (http://www.hp.com/servers/proliantml350).
To install the component:
1. Install the power cable ("Installing a hard drive expansion cage power cable" on page 54).
IMPORTANT: When installing the optional two-bay LFF expansion hard drive cage, do not
reconnect SAS cable B.
2. Remove the two bezel blanks closest to the primary hard drive cage.
3. Using a T-15 Torx screwdriver, remove the primary hard drive cage screws.

Table of Contents

Other manuals for HP PROLIANT ML350 G6

Related product manuals