EasyManua.ls Logo

HP ProLiant ML370 - Re-Entering the Server Serial Number

HP ProLiant ML370
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removal and Replacement Procedures
2-60 HP ProLiant ML370 Generation 3 Server Maintenance and Service Guide
Re-entering the Server Serial Number
After you replace the system board or clear NVRAM, you must re-enter the server serial
number. To re-enter the serial number:
During the server startup sequence, press the F9 key to access RBSU.
1. Select the System Options menu.
2. Select Serial Number. The following warning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the
system during the manufacturing process and should NOT be
modified. This option should ONLY be used by qualified service
personnel. This value should always match the serial number
sticker located on the chassis.
Press the Enter key to clear the warning.
3. Enter the serial number and press the Enter key.
4. Press the Escape key to close the menu.
5. Press the Escape key to exit RBSU.
6. Press the F10 key to confirm exiting RBSU. The server will automatically reboot.

Table of Contents

Other manuals for HP ProLiant ML370

Related product manuals