20 Install the server enclosure in a rack
Hardware Description Application
Redundant network switches Required number of switches. Connects devices to a network.
The number of switches depends
on your network configuration.
Redundant Uninterruptible Power
Supply (UPS)
Required number of UPS
devices.
Provides temporary power to the
server in the event of a complete
power outage.
Rack requirements
Each server ships with a sliding rail kit. The sliding rails allow you to fully extend the enclosure out of the
rack for service.
Caution:
See the Rack Installation Instructions supplied with the rail kit for safety and installation
instructions.
The racks you use for each server must meet these requirements:
The sliding rails support tool-free mounting in 19-inch, EIA-310-E compliant square-hole, 4-post racks,
and also support tooled mounting in threaded 4-post racks.
Each enclosure is 2U. Ensure the rack has sufficient space for all enclosures.
For full power redundancy across all servers, you need a rack with two power distribution units (PDU)
feeding separate outlet strips, with sufficient vacant outlets on each strip.
Ensure the rack is installed and stabilized or bayed according to the manufacturer's instructions.
WARNING:
When servicing an enclosure in a rack, extend only one enclosure at a time to prevent the
rack from tipping.
Rack installation guidelines
There are guidelines to help you successfully install each server in a rack.
Follow all safety guidelines stated in the documentation that came with the rack, particularly when
installing components into the locations at the top of the rack.
Ensure the rack meets the requirements.
Install the servers in the same rack when possible.
Install the servers in a rack starting from the bottom of the rack.
Always install the servers in a horizontal position, or you void your warranty and support contract.
Install the server enclosure in a rack
You install the rails, which are included in the shipping carton, at the lowest available U space in the rack
enclosure. You then work up from the bottom of the rack to add additional rails.
Before you begin
You have read the safety instructions in the Product Information Guide supplied with your system.